Canal hydraulic design
Each reach has its discharge, bed slope, Manning's n and side slope. Manning's formula Q = A R^(2/3) S^(1/2) / n gives the section fixed by the bed width / depth ratio, the bed width or the depth; Lacey's regime theory (unlined alluvial canals) gives its own section and slope from the silt factor.
Free board from IS 10430 (lined) or IS 7112 (unlined) unless typed. The velocity is checked against 2.5 m/s (lined) / 1.0 m/s (unlined) and silting below 0.3 m/s, the Froude number against 0.8. The bed levels run down from the head bed level at each reach's slope.
Apply to the sections makes a template per reach (bed, inner slopes to the bank top, banks, outer slopes) with the full supply level as its own layer, puts the bed levels in as the formation, assigns the reaches and – if ticked – applies the templates. The lining area and volume can be priced in the BOQ (Canal lining).
Commands
CXCANALCanal hydraulic design…
Bed width, full supply depth, velocity, Froude number and free board of each reach by Manning's formula (fixed by B/D ratio, bed width or depth) or Lacey's regime theory for unlined alluvial canals, free board from IS 10430 / IS 7112 – then templates with the full supply level, bed levels as the formation and the lining quantity.
CXTEMPLATETemplates and assemblies…
Template master: horizontal, vertical, gradient, slope and daylight elements; assemblies that write several layers (formation, blanket, subgrade) in one go.
CXAPPLYApply template to sections…
Apply templates or assemblies per section; final level = existing − drop; shift centre; fill final.